Ok– so it’s not the most glorifying vocation through the eyes of John Q. Public– we get that. As a chimney sweep, I’m not rushing into burning buildings or otherwise finding the spotlight.

But we save lives. Whether saving physical life– as from carbon monoxide poisoning or a chimney fire, or physical things— like your home, business and belongings.

On January 13, 2000, the National Fire Protection Association adopted code NFPA 211 (Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances) and defined 3 inspection levels.

Here’s what it says:

Level 1 Inspections

If your appliance or your venting system has not changed and you plan to use your system as you have in the past, then a Level 1 inspection is a minimum requirement. A Level 1 inspection is recommended for a chimney under continued service, under the same conditions, and with the continued use of the same appliance.

In a Level 1 inspection, your chimney service technician should examine the readily accessible** portions of the chimney exterior, interior and accessible* portions of the appliance and the chimney connection. Your technician will be looking for the basic soundness of the chimney structure and flue as well as the basic appliance installation and connections. The technician will also verify the chimney is free of obstruction and combustible deposits.

Level 2 Inspections

A Level 2 inspection is required when any changes are made to the system. Changes can include a change in the fuel type, changes to the shape of, or material in, the flue (i.e. relining), or the replacement or addition of an appliance of a dissimilar type, input rating or efficiency.

Additionally, a Level 2 inspection is required upon the sale or transfer of a property or after an operation malfunction or external event that is likely to have caused damage to the chimney. Building fires, chimney fires, seismic events as well as weather events are all indicators that this level of inspection is warranted. A Level 2 inspection is a more in-depth inspection than a Level 1 inspection.

When a Level 1 or Level 2 inspection suggests a hidden hazard and the evaluation cannot be performed without special tools to access concealed areas of the chimney or flue, a Level 3 inspection is recommended. A Level 3 inspection addresses the proper construction and the condition of concealed portions of the chimney structure and the flue.

Removal or destruction, as necessary, of permanently attached portions of the chimney or building structure will be required for the completion of a Level 3 inspection. A Level 2 inspection includes everything in a Level 1 inspection, plus the accessible portions of the chimney exterior and interior including attics, crawl spaces and basements. It will address proper clearances from combustibles in accessible locations.

There are no specialty tools (i.e. demolition equipment) required to open doors, panels or coverings in performing a Level 2 inspection. A Level 2 inspection shall also include a visual inspection by video scanning or other means in order to examine the internal surfaces and joints of all flue liners incorporated within the chimney. No removal or destruction of permanently attached portions of the chimney or building structure or finish shall be required by a Level 2 inspection.

Level 3 Inspections

A Level 3 inspection includes all the areas and items checked in a Level 1 and a Level 2 inspection, as well as the removal of certain components of the building or chimney where necessary. Removal of components (i.e., chimney crown, interior chimney wall) shall be required only when necessary to gain access to areas that are the subject of the inspection. When serious hazards are suspected, a Level 3 inspection may well be required to determine the condition of the chimney system.

Inspection Definitions

* Accessible: May require the use of commonly available tools to remove doors, panels or coverings, but will not damage the chimney or building structure or finish.

** Readily Accessible: Exposed, or capable of being exposed, for operation, inspection, maintenance or repair without the use of tools to open or remove doors, panels or coverings.

Filed Under: chimney sweep Tagged With: chimney inspection, CSIA, faqs

Request Service

Service Menu:

  • Chimney Inspection
  • Chimney Sweep
  • Chimney Caps
  • Chimney Crown Repair
  • Chimney Flashing Repair
  • Chimney Waterproofing
  • Animal Removal

Hi Don,

We had over a day of rain and it stayed dry inside. The stone was nice and dry. The Chimney Saver sealant is doing its job. Thank you for your work and for following up.

Carol from White Bluff Home Owner

Don's Chimney Service Logo

Why Do You Need a Chimney Inspection? Yes, we know this is Texas. Preparing for the winter is pretty basic: drag the winter clothes out, … More...

Don’t Get Burned

Save an Extra 15%!

Save 25% Now

  • Services
  • FAQs
  • Testimonials
  • Contact

© 2023 Don's Chimney Service · Site Powered by Computer Solution Technology Services · Privacy Policy · Terms of Use